SOL-814 T1+T2 1/1 RCD 3F 25 A T2 prefabricated AC/DC switchboard Iontec

SOL-814 DC T1+T2 1/1 AC RDC 3F 25 A T2 switchgear - 1 MPPT - surge arrester 1200 V

260.25excl. VAT

260.25 € incl. VAT
Zapytaj o cenę
SOL-814 T1+T2 1/1 RCD 3F 25 A T2 prefabricated AC/DC switchboard IontecSOL-814 T1+T2 1/1 RCD 3F 25 A T2 prefabricated AC/DC switchboard Iontec260.25 €

Your Query is sent.

  •     *Required Fields

Loading

.

The ACDC T1+T2/T2 electrical switchgear provides full protection of AC and DC circuits of a photovoltaic installation from the effects of surges. Its design is suitable for surface mounting.

The product consists of a housing, transparent door, TH-35 mm rails, N+PE terminals, front cover with cut-outs for apparatus, chokes, caps, and mounting parts.

Electrical and mechanical parameters of the enclosure:

  • Designed for surface mounting
  • Manufactured in accordance with EN 60670, EN 62208
  • Rated current In 63 A
  • IP65 rating
  • Protection class II
  • Rated insulation voltage Ui: 690 V AC, 1000 V DC
  • Glow wire test: 650°C
  • Impact resistance: IK08
  • Operating temperature: -25°C to +60°C
  • Halogen-free recyclable plastic

Overcurrent circuit breaker NOARK Ex9BN 3P:

  • B curve
  • Manufactured in accordance with IEC/EN 60898-1
  • Rated short-circuit breaking capacity ICN: 6 kA
  • Rated switching voltage 230/400 V AC

DC DEHN Combo 1200 V typ 1+2 surge protector:

  • PV T1+T2 (Class I+II, Type 1+2, B+C)
  • To be used in accordance with the standard: PN-HD 60364-7-712
  • Rated discharge current In: 20 kA (8/20 μs)
  • Voltage protection level: 3.8 kV
  • Size: 4 modules
  • Maximum PV voltage Ucpv: 1200 V
  • Tripping time tA 25 ns
  • Optional auxiliary contact to indicate insert status

AC surge arrester  NOARK Ex9UE2 20 4P 275:

  • T2 (Class II, Type 2, C)
  • Rated discharge current In (8/20 us) per phase: 20 kA
  • Continuous operating voltage Uc: 275 V per phase
  • Size: 4 modules

Residual-current circuit breaker Ex9L-N:

  • Switch type: A
  • Rated current: 40 A
  • Rated residual current: 100 mA
  • Number of poles: 4
  • Short-circuit withstand capacity: 6 kA
SOL-814

Attributes

Switchgear type
Prefabricated
Type of protection
DC/AC
Max. voltage [V]
1000
Max. current [A]
25
Feed-in phases
3
Number of MPPT inputs
1
Switchboards
24-pole
Dimensions [mm]
325 x 390 x 160
Type of surge arrester AC
T2
Type of surge arrester DC
T1+2
Residual current device
Yes