SOL-809 T2 T2 1/1 prefabricated DC/AC RCD switchboard Iontec

SOL-809 DC T2 AC RDC 3F 50 A T2 1/1 switchgear - 1 MPPT - surge arrester 1000 V

239.50excl. VAT

239.50 € incl. VAT
Zapytaj o cenę
SOL-809 T2 T2 1/1 prefabricated DC/AC RCD switchboard IontecSOL-809 T2 T2 1/1 prefabricated DC/AC RCD switchboard Iontec239.50 €

Your Query is sent.

  •     *Required Fields

Loading

.

The ACDC T2/T2 electrical switchgear provides full protection of DC circuits of a photovoltaic installation from the effects of surges. Its design is suitable for surface mounting.

The product consists of a housing, transparent door, TH-35 mm rails, N+PE terminals, front cover with cut-outs for apparatus, chokes, caps, and mounting parts.

Electrical and mechanical parameters of the enclosure:

  • Designed for surface mounting
  • Manufactured in accordance with EN 60670, EN 62208
  • Rated current In 63 A
  • IP65 rating
  • Protection class II
  • Rated insulation voltage Ui: 690 V AC, 1000 V DC
  • Glow wire test: 650°C
  • Impact resistance: IK08
  • Operating temperature: -25°C to +60°C
  • Halogen-free recyclable plastic

Overcurrent circuit breaker NOARK Ex9BN 3P:

  • B curve
  • Manufactured in accordance with IEC/EN 60898-1
  • Rated short-circuit breaking capacity ICN: 6 kA
  • Rated switching voltage 230/400 V AC

NOARK Ex9UEP 20 3P 1000 V DC surge protector:

  • PV T2 (Class II, Type 2, C)
  • Designed in compliance with 50539-11
  • Rated discharge current In: 20 kA (8/20 μs)
  • Maximum discharge current Imax: 40 kA (8/20 μs)
  • Size: 3 modules
  • Rated switching voltage Un: 1,000 V
  • Thermal protection function
  • Optional auxiliary contact to indicate insert status

AC surge arrester  NOARK Ex9UE2 20 4P 275:

  • T2 (Class II, Type 2, C)
  • Rated discharge current In (8/20 us) per phase: 20 kA
  • Continuous operating voltage Uc: 275 V per phase
  • Size: 4 modules

Residual-current circuit breaker Ex9L-N:

  • Switch type: A
  • Rated current: 63 A
  • Rated residual current: 100 mA
  • Number of poles: 4
  • Short-circuit withstand capacity: 6 kA
SOL-809

Attributes

Switchgear type
Prefabricated
Type of protection
DC/AC
Max. voltage [V]
1000
Max. current [A]
50
Feed-in phases
3
Number of MPPT inputs
1
Switchboards
24-pole
Dimensions [mm]
325 x 390 x 160
Type of surge arrester AC
T2
Type of surge arrester DC
T2
Residual current device
Yes